Logging Probe Series

2022-06-28

1656381144234969.jpg

GJ-451/SGJ-451 Cementing probe 

 Check cementing quality

 Working mode:nondirecting measurement

 Measuring range of time-of-arrival: 666μs/m

 Short distance reception: 883.3312 μs/m

 Transmit cycle: 106ms

 Frequency of sound wave: 20KHz±5KHz

 Calibration accuracy: ±2 μs/m

 Amplitude log range:0 to 10V,error:≤±5%

 Measuring range of gamma: 0 to 1000cps,error:≤±5%

 easuring range of magnetic location: ±255 yards

 RS232 port:transmit data

 Dimensions:Ф45×2000mm

 Maximum depth: 3000 meters

 Measuring mode: continuous measurement

 Working temperature: -10℃ to 70℃

 Pressurization: less than 30Mpa

 Weight: 13kg


 M552 Combined sidewall probe 

 Application

 Have a good performance of stratum Lithology acquisition, strata division, resistivity, porosity and volume density determination so that makes it a incompensible part of the series probes. It can valuate the radiate minerals content such as K and U, tell radiate minerals from non-radiate ones and also can serves as part of other methods.

 Specification

 Measured parameters: double-spaced compensated density (DsCD), Natural Gamma, Three direction laterolog, Caliper and spontaneous potential

 Data transmitter: 8-bit serial output

 Work environment: -10℃ to 70℃

 Dimensions:Ф50×2950mm (divided to two segments)

 Probe weight: ≤28 Kg,

 Pressurization: less than 20Mpa

 DsCD (double-spaced compensate density log)

 The source is based on oriented-emitting, and explorer uses long- or short-spaced oriented receiver which is wall-sticking can reduce affect borehole type to the density measurement.

 Work source strength: 100mCi137Cs radioisotopes. 

 Short spacing: 200mm, Long spacing: 350mm 

 Glimmers body: Nal(T1), Ф23×40mm 

 Photomultiplier Tube: GDB23 

 Counting range: 0 to 32000cps 

 Measurement density range: 1 to 4g/cm3 

 Measurement relative error: 5% 

 Stability: work a continual 4-hour (5μCi or C s137 source), and the output changes less than 5%

 Natural Gamma logging 

 Glimmers body: NaI(T1), Φ23×60mm 

 Photomultiplier Tube: GDB23 

 Measurement range: > 30Kev γ-rays 

 Counting range: 0 to 32000cps 

 Stability: be able to work a continual 4-hour, and the output change no more than 3.5%(an average of 100 data set).

 Trace-interval disturbance: Values the source-loaded traces can disturb the natural ones are no more than 0.5%.

 Three-lateral Resistivity laterolog 

 Range of measurement: 0 to 2kΩ 

 Scaling accuracy error: <5% 

 Stability: can work a continual 4-hour, and its output changes no more than 5%.

 Main electrode length: 25mm, electrodes full length is 455mm

 Caliper logging 

 phole device controls the downhole probe, make it instantly fold or unfold the legs.

 Measurement range: φ50mm to φ300mm 

 Measure sensitivity: 0.5mm 

 Scale accuracy error: <3% 

 Spontaneous potential 

 Measuring range: -2V to +2V 

 Measuring accuracy: ±2.5 mv 

 JCS-1/SJSC-1 Digital inclination probe 

 Vertex angle range: 0 to 60°

 Vertex angle accuracy: ≤0.1°

 Azimuth range: 0 to 360°

 Azimuth accuracy: if 2°< vertex angle≤3°,±4°; and if vertex angle > 3°, ±2°.

 Work temperature: 0 to 80℃

 Dimensions: Φ45×1200mm

 Weight: ≤ 4Kg (weight-gained bar is 5Kg)

6.36 KG (3000 meters)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Main performance: an axis-oriented system of point-by-point or continual measuring, digital output, easy to use and reliability.


 S524/SS524 Acoustic wave probe 

 Application

  It is a non-oriented measurement of single-source double-receiver.Determination including lithology, strata porosity, gas-contained strata, and fault detection. Make use of any other log resources, can ascertain the degree of moisture content of strata, and if execute the acoustic logging, we may check out the cement glue quality of borehole tube.

  Measurement range: 125 to 555μs/m

 Receiving nearby: 0 to 833.3312μs/M

 Source intervals: 106ms

 Source wave frequency: 20KHz±5KHz

 Scale accuracy: ±5μs/M

 Source spacing: 0.5M to 0.7M

 Spacing : 0.2M

 Transmission mode: 8-bit digital data

 Environment temperature: -10℃ to 70℃

 Dimensions: φ50×2240mm, φ55×1861mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight: 11.2kg, 13kg (3000m)


 M433/SM433 Double-density probe

 Source intensity: 30mCi137Cs radioisotopes,Long/short-spaced natural gamma probes are all be used.

  Scintillating material: Nal(T1), Φ23×60m

 Photomultiplier Tube: GDB23

 Count range: 0 to 32000cps

 Long spacing: between 400 to 500mm adjustable.

 Short spacing: between 250 to 350mm adjustable

 Density measuring range: 1 to 4g/cm3

 Natural gamma measuring range: 1 to 10000API

 Dimensions: Φ45×1750mm,Φ50×1804mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Digital transmitter: 8-bit serial output

 Weight: 8.4kg, 10.7 kg (3000m)

  Application

  It is specially apply for exploring the dry borehole. The method that compensated density can divide the strata, determine the porosity of rock and density of volume. Naturalγis applied to identify lithology, locate the strata, estimate the sludge content, tell the rock strata from the shale one. Evaluate the radiate minerals that have a content of potash, anhydrite or U, and find out the non-radiate minerals such as salty rock, non-water gypsum and so on.


 W422/SW422 Temperature and liquid resistivity combined probe

 Measuring range: -10℃ to 100℃

 Measurement sensitivity: ≤0.05℃

 Temperature-sensing time: ≤1s

 Temp-measuring derivation: ≤5%

 Dimensions: φ40×1330mm,φ50×1230mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight: 6.7kg, 7.8kg (3000m)

  Stability: the output changes of no more than 3% for 4 hours of continuous operation under the same

  conditions 

 Application

 locate the aquifer bed or thermal spring in the geothermal survey; search for petroleum and gases

 X411/SX411 Three-lateral direction resistivity laterolog probe

  Measuring range: 0 to 10KΩm

 Output signal: 0 to 9V DC

 Work temperature : -10℃ to 60℃

 Dimensions:ф40×1416mm, ф50×1416mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight: 6.6kg,7.2kg (3000m)

 Application: determines the resistivity of rock strata.


 H411/SH411 Magnetic susceptibility probe 

  Measuring range: 1 to 10000×10-4 SI

 Output signal: 0 to 9V DC voltage

 Scale accuracy: ≤5%

 Stability error: ≤10%

 Work temperature: -10℃ to 60℃

 Dimensions: φ45×1200mm,φ48.5×1377mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight: 5.6 kg; 6.9kg (3000m)

 Application: seeking for magnetic iron ores

 J411/SJ411 Caliper probe 

  Measuring range: 40mm to 300mm

 Output signals: 0 to 9V DC voltage

 Sensitivity: 1mm

 Work temperature: -10℃ to 60℃

 Dimensions: φ40×1320mm, φ50×1324mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight; 6.6kg,7.2kg (3000m)

 Applications: check the integrity of well and provide additional information to help.

 J511/SJ511 Big-hole caliper probe 

  Measuring range: 75mm to 700mm

 Output signal: 0 to 9V DC voltage

 Sensitivity: 2 mm

 Dimensions: φ40×1620mm, φ50×1324mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight: 6.5kg, 7.2kg (3000m)

 Application: used for big-bore logging


 NP442 Multi-channel spectrum probe 

  Measuring range: 0.3Mev to 3Mev full differential spectrum

  Resolution: standard-source C137s(0.66Mev) ≤15%

 Time count range: 4″,12″,20″,28″,36 by manual

 Integrated nonlinear: ≤2%

 Differential nonlinear: ≤±5%

 Dead time: < 50μs

 Stable spectrum source: 133Ba, 5μCi

 Pressurization: less than 20Mpa

  Dimensions: Main probe: φ45×1330mm, Probe 1st: φ40×800mm,Probe 2nd: φ65×800mm

  Stability: the biggest error is less than 5%, which the average value of each data set comparing with the total average.

 Application: in research of uranium ore, divide the strata, and tell the oil stratum from the water zone.

 Z422/SZ422 Neutron combined probe 

  Measuring parameters: N-N, natural gamma

 Neutron activated source: 241Am-9Be, 1Ci

 Counting range: 0 to 10000cps

 Proportional counter : 39He

 Natural gamma:

 Scintillating material: Nal(T1), Φ23×60m

 Photomultiplier tube type: GDB23

 Measuring range: >30Kev gamma ray

 Counting range: 0 to 32000cps

 Work temperature:-10℃ to +60℃

 Dimensions: φ45×2050mm,φ50×2000mm (3000m)

 Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m)

 Weight: 7.8kg, 8.6kg (3000m)

 R411/SR411 Natural gamma probe 

  Measurement parameter: nature gamma

 Dimensions: ф40mm×870mm;ф45mm×870mm (3000m)

 Pressurization: ≤ 20Mpa

 Digital transmission: 8 bits serial output

 Operating temperature: 0℃ to +60 ℃

 Weight: 5.7 kg; 6.8 kg (3000m)

 Range: more than 30Kev

 Scintillator: NaI(Tl)、φ23×60mm

 Photomuitplier: GDB23

 Counting range: 0 to 32000 cps


 Y411 fluorescence probe 

 Measuring range: 42Mo to 82Pb when using 241Am as an activated source, and can be amplified to 0.2U as 109Ge

 Resolution: more than 60% for Sn (SnKa=25.27Kev)

 Applications: in search of metal minerals, and analyze quantitatively rock quality.

 LLY-1/SLLY-1 flow probe 

  Flux unit: tons per hours, impulse scale.

 Dimensions: ф51×1300mm; ф50×1270mm (3000m)

 Pressurization: ≤15 MPa; ≤30 MPa (3000m)

 Work temperature: -10℃ to 85℃

 Weight: 8.7 kg; 9.5kg (3000m)


 JD-1 Conventional resistivity log probe 

  Dimensions: φ40×1330mm (A0.9M0.1N),φ40×2332mm (A1.6M0.4N)

  Pressurization: less than 15Mpa

 Measurable parameters: SP, NR, and LR


  Application

  Ascertain the thickness of strata, and stratum water resistivity, estimate clay content, divide the permeable strata and sections in erosion belt in the gasoline resistivity log, and effected thickness of oil stratum.

JD-3 Soft-electrode probe  

  The spacing of the four electrodes is up to you

 Measuring parameters: SP, NR, LR and IP

 Measuring range: 0 to 10KΩm

 Measurement sensitivity: 0.04Ωm

 Scale accuracy error: <5%

 Pressurization: less than 15Mpa

 IP: its specifications are up to a ground meter.

Applications: thickness of rock, water resistivity, clay content, permeability, resistivity of erosion belt, lithology and oil stratum thickness.


Related Product

JCX-3 Three-Component Borehole Magnetometer

JGS-3 Integrated Digital Logging System

JGS-1B Intelligent Engineering Logging System

JKX-2 Full Hole Wall Imaging System

Logging Probe