Electrical Product Fire Testing Equipment

IEC 60695-2 Needle Flame Tester

2022-10-25

IEC 60695B-.png

  Introduction:  

The design and production of the Needle Flame Tester follow national requirements GB4706.1-1998. The tester is used for small-flaming ignition experiments in the lighting, low-voltage electrical equipment, home appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, electrical connectors, accessories, and other electrical and electronic equipment and parts industries, as well as component research, production, and quality control departments.


A needle burner of a standard size (0.9 mm) is used by the needle flame tester,and burns the sample at a 45-degree angle using a particular gas (butane). We examine the sample burning scenario, burning time, and burning length to determine the ignition danger of the small flame caused by equipment fault situations.


  Standard:  

GB4706.1,

GB5169.5-2008, 

IEC60695-2-2

Test procedure

Warning note

Precautions must be taken to safeguard the health of the personnel conducting tests against: the risks of explosion or fire; the inhalation of smoke and/or toxic products; toxic residues.

1、 The room or compartment in which the test is made shall have adequate dimensions to ensure that the test is carrled out in a substantially draught-free atmosphere and with an adequate supply of air.

2 、 Unless otherwise prescribed in the particular spectrification, the specimen is available in the most defavorable position in normal use. The SPIMEN fixing devices must not have any influence on the effect of the test flame or on the propagation of flames, other than that which they would have in the normal conditions of line.

3 、 During the adjustment of the test flame, we must avoid any influence of the heat derived on the specimen.

4 、 The test flame is applied to the partile of the surface of the specimen likely to be affected by flames occurring as a result of normal use or a default, or the continuation of accidental application of An ignition source what it is. To apply the most defavorable trial flame, you can fold the baking tube. The application point and the application duration of the test flame must be prescribed in the particular specification. When the test flame has positioned such a fagon that at least the point of the flame is in contact with the surface of the specimen, the Br0leur should no longer be a decree. The test flame is removed after the prescribed duration. See in Figure 1, examples of test position.

5 、 Unless otherwise prescribed in the special specification, the Essay is carried out on three specimens.

6 、 If the special specification is required, the Essal is carried out in addition to one point of the same specimen and, in this case, it must be ensured that a deterioration caused by the preceding trials does not affect The result of the current Essal.

IEC60695-11-5 etc.


  Technical Parameters:  

1. A stainless steel needle burner with no air access, an inner diameter of 0.5 to 0.1mm, and an exterior diameter of no more than 0.9mm.

2. The burner angle: 45-degree incline or vertical (for altering and measuring the flame height) (the test).

3. Almost all of the combustion gases are propane or butane.

4. White pine plank with a thickness of 10mm is used as the ignited bedding layer, with a typical tissue paper layer covering the surface applied at a lower flame from 200mm to 5mm.

5. 0 to 1000 °C is the temperature range.

6. Completion of the flame temperature criteria, which range from 100 2 °C to 700 3 °C, should take 23.5 1.0s.

7. 12mm + 1mm is the height of the flame.

8. Adjustable burning time of 0 to 999.9 seconds, usually set at 30 seconds.

9. Holding burning time: 0 to 999.9 seconds, auto-recording, manual pause.

10. Test area: 0.5 m3, black backdrop (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements).

11. K-type insulation-sheathed thermocouple, measuring approximately 0.5 mm.

12. Test program for an independent ventilation system with automatic control.

13. Exhaust 100mm, dimensions 1120 (L) 520 (W) 1250 (H).

14. Test power: 220 volts, 50 hertz, ac.



  Welcome to contact us: 

Contact Person: Kiana Feng

Whatsapp/Wechat: +86 15922982738

Mobile: +86 15922982738

Fax: +86-23-62940030

Email: gold20@hy-industry.com